Storage silos use the same inspection protocol as batch machines. Check the structure thickness, especially the cone area. Mark any thin areas for repair or replacement.
A/C, shower, and combustion dampers need to be inspected for wear or damage. Replace or repair as necessary. Inspect each fly and mixing tip for the following problems:
The main burner and thermal oil heater complete your combustion system. Burner maintenance/cleaning and regular tuning are important for every BT utilizing the fuel available. Test, evaluate and adjust your burners as needed to optimize performance.